来源: 发布时间:2021年10月12日

氧氮氢分析仪是快速、准确分析氧、氮、氢元素的、高性能仪器,整机采用模块化、一体化设计,即主机由可靠的脉冲电极炉、高灵敏高精度的检测系统、布局合理和气密性好的气路系统、可靠耐用的电源系统、稳定的电路系统、高校节能的水循环散热系统等六个**的硬件模块单元组成。

氧氮氢分析仪的测量原理:

测量范围非常***。分析样品时,样品被称重后放到样品端口中,然后用载气进行冲洗,防止大气(含氧气和氮气)进入到炉子系统中。

石墨坩埚在脉冲炉中脱气,以尽量减少自带的污染。经过稳定阶段后样品落入坩埚中并熔融。样品中的氧与石墨坩埚中的碳反应生成一氧化碳。氮和氢以单质的形式释放。载气和样品气体通过粉尘过滤网后再进入到氧化铜催化炉中,将一氧化碳氧化成二氧化碳。

二氧化碳进入到红外池中用于测定氧含量,被测后的气体导入化学试剂管,这时二氧化碳和水被化学试剂除去,氮元素通过热导检测池含量被测定。测量氢时,载气换为氮气,样品气体通过舒茨试剂而不是氧化铜催化剂。测氧和氮时也可采用更廉价的氩气作为载气。 **的动态流量补偿(DFC)保证热导池气体流量、压力恒定。进口分析仪采购

进口分析仪采购,分析仪

Procedure - Solid Samples

Prepare the instrument as outlined in the operator's instruction manual.


Determine the instrument blank.

Login a minimum of 3 Blank replicates.

Press the Analyze button on the instrument screen. After a short delay, the loading head slide-block will open. Place a 502-344 Nickel Basket into the loading head.

Note: samples using automation should be placed in the appropriate autoloader position before starting the

analysis sequence. Once the sequence has started, the automatic analysis will start and end automatically.


山东专业分析仪厂家供应氧高低双量程采用3个碳红外检测一氧化碳和二氧化碳,保证准确定量。

进口分析仪采购,分析仪

氧氮氢分析仪的常见故障及解决方法

仪器启动时显示。没有水流。系统分析电流切断,分析停止。这是水流探测器不正常,水泵不工作,管道堵塞。将仪器的右面板取下,观察水流探测器,用手挤压补水塑料水瓶,发现水流正常,显示正常,证明水流探测器正常,管道畅通。启动循环水泵,但分析仪显示没有水流,此时可判定水泵不正常。打开水泵转子密封口,启动泵发现电机正常运转,此时关闭进水,拆下水泵,发现叶轮脱落。经了解,判定是由于外部冷却水停水,仪器内循环水温过高(水温应≤70℃),致使叶轮(叶轮材料PVC)热胀并脱轴。用粘合剂粘合叶轮后再粘于叶轮轴上,待粘合剂凝固后试车,仪器运行正常。

LECO—Your source for total analytical solutions


CS CS 844 and 744 Series: Carbon/Sulfur by Combustion

Carbon and sulfur determination by combustion infrared detection

Quick, accurate, and affordable determination for both production control and research

Calibration, analysis, evaluation, and diagnostic functions accessible via user-friendly brand software



GDS GDS 500A and 850A Atomic Emission Spectrometers

Spectral range from 120 to 800 nm

Continuous profile of concentration/thickness

Large, dynamic range with concentrations from ppm to 100% by weight

Short analysis time (minutes)





装有自动旁路阀的可快速拆装氧水捕集装置。

进口分析仪采购,分析仪

Procedure – Powder/Chip Samples

Determine the instrument blank.


Press the Analyze button on the instrument screen, the lower electrode will close and the analysis sequence will start and end automatically.


Repeat steps 2b through 2g a minimum of three times.


Set the blank following the procedure outlined in the operator's instruction manual.


Instrument calibration/drift correction.

Login a minimum of three Standard reps.


Weigh approximately *** grams of a calibration/drift standard into a *** Nickel Capsule; enter the mass and standard identification into appropriate rep fields. If applicable, place the nickel capsule in the appropriate autoloader position.


Note: LECO Reference Materia***o not require preparation. See preparation statement on the reference material certificate. Solid Standards may be used to calibrate when chip or powder standards are not available.




为可**的Cornerstone 氧氮氧分析软件采用触摸屏界面使用户达到分析控制、15法设定、在线诊断、数据报告。元素分析仪厂家供应

ONH836仪器通过***采纳客户的反馈意见和创新设计。进口分析仪采购

Procedure - Solid Samples:

--Instrument calibration/drift correction.

Place the nickel basket containing the calibration/drift standard into the open port at the top of the loading head.

Press the Analyze button on the instrument screen again, the loading head slide-block will close and the lower electrode will open.

Clean the upper and lower electrode manually, or, if applicable, remove the crucible and press the analyze button to clean with the automatic cleaner.



进口分析仪采购